Carrier Aquazone 50WD handleiding
Handleiding
Je bekijkt pagina 4 van 84

4
Fig. 1 — 50WD Model Number Nomenclature
Electrical Options (12)
NOTE(S):
a. Option card board is provided with selection of
HGRH/WSE/BE options and without TruVu DDC.
b. ULL represents < 2% air leakage option.
LEGEND
BE — Boilerless Electric Heat
CA ECM — Constant Airflow ECM
CB — Compressor Blanket
CCF — Closed Cell Foam Insulation
CO — Cooling Only
CT ECM — Constant Torque ECM
DP — Differential Pressure Flow Switch
ECM — Electronically Commutated Motor
EMS — Energy Management Switch
HGBP — Hot Gas Bypass
HGRH — Hot Gas Reheat
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
5 0 W DA 0 2 4 G B A 3 A A – A
Model Series (1-2)
50 = Packaged WSHP Unit
Tier (3-4)
Cabinet Configuration (5)
Nominal Capacity MBH (Tons) (6-8)
007 = 7 (1/2)
009 = 9 (3/4)
012 = 12 (1)
015 = 15 (1-1/4)
018 = 18 (1-1/2)
024 = 24 (2)
030 = 30 (2-1/2)
036 = 36 (3)
042 = 42 (3-1/2)
048 = 48 (4)
060 = 60 (5)
070 = 70 (6)
Airflow Configuration (9)
Controls — Option/Transformer (10)
B = UPM/75VA
D = UPM + BE/75VA
a
E = UPM + TV DDC/100VA
H = UPM + SR/75VA
K = UPM + PR/75VA
M = UPM + ER/75VA
P = UPM + BE + PR/75VA
a
R = UPM + BE + SR/75VA
a
T = UPM + BE + SR + PR/75VA
a
V = UPM + SR + PR/75VA
X = UPM + EMS + SR/75VA
Z = UPM + EMS + PR/75VA
2 = UPM + EMS + SR + PR/75VA
4 = UPM + EMS + BE/75VA
a
6 = UPM + EMS + BE + SR/75VA
a
8 = UPM + EMS + BE + PR/75VA
a
3 = 208-230/1/60
4 = 265/1/60
5 = 208-230/3/60
6 = 460/3/60
B = 208-230/1/60 with Disc.
-
C = 265/1/60 with Disc.
D = 208-230/3/60 with Disc.
E = 460/3/60 with Disc.
H = 208-230/3/60, 65 kA SCCR
G = 208-230/1/60, 65 kA SCCR
J = 265/1/60, 65 kA SCCR
N = 208-230/1/60, 15 kW E-heat (dual-point power)
Q = 208-230/1/60, 5 kW E-heat (dual-point power)
S = 208-230/1/60, 10 kW E-heat (dual-point power)
Sound and IAQ Options (13)
A = None (Std Insulation)
B = Closed Cell Foam Insulation (CCF)
D = Ultra -Low -Leak Cabinet (ULL), CCF + 2 in. MERV 8
b
F = 2 in. MERV 8 Filter, Std Insulation
G = 2 in. MERV 8 Filter, CCF
H = 2 in. MERV 13 Filter, Std Insulation
J = 2 in. MERV 13 Filter, CCF
K = 4 in. MERV 13 Filter, Std Insulation
L = 4 in. MERV13 Filter, CCF
M = ULL, CCF + 2 in. MERV 13
b
P = ULL, CCF + 4 in. MERV 13
b
U = Compressor Blanket (CB), Std Insulation
V = Compressor Blanket (CB), CCF
W = CB + 2 in. MERV 8, Std Insulation
3 = ULL, CCF + CB + 2 in. MERV 8
b
4 = ULL, CCF + CB + 2 in. MERV 13
b
5 = ULL, CCF + CB + 4 in. MERV 13
b
Hydronic Options (14)
OPTION
WATER COIL
Copper
Cupro-
Nickel
None
A
J
B
K
Auto-Flow Reg. (REG)
C
L
Flow Proving Switch (DP)
D
M
VLV + REG
E
N
VLV + DP
F
P
VLV + REG + DP
G
Q
REG + DP
H
R
ORIENTATION
RETURN
DISCHARGE
MOTOR
CA ECM
Horizontal
Right
Back
N
Right
Left
P
Left
Back
Q
Left
Right
R
Vertical
Right
Top
S
Left
Top
T
ORIENTATION
FILTER
ACCESS
WATER CONNECTION
Front Left
Front Right
Horizontal
A
B
C
D
Vertical
E
F
Miscellaneous Options (15)
– = None
A = Waterside Economizer (WSE)
a
B = A2L Leak Detection (LD)
C = WSE + LD
a
Design Revision (16)
A = Initial Release
MHGRH — Modulating Hot Gas Reheat
PR — Pump Relay
REG — Auto Flow Regulator
SR — Compressor Status Relay
STD — Standard
TV DDC — TruVu Direct Digital Controller
ULL — Ultra Low Leak Cabinet
UPM — Unit Protection Module
VLV — 2-Way Solenoid Valve
WSE — Water Side Economizer
WSHP — Water Source Heat Pump
P = 208-230/1/60, 20 kW E-heat (dual-point power)
Z = 460/3/60, 65kA SCCR
C = Extra Quiet Package (EQP)
X = CB + 2 in. MERV 8, CCF
Y = CB + 2 in. MERV 13, Std Insulation
Z = CB + 2 in. MERV 13, CCF
1 = CB + 4 in. MERV 13, Std Insulation
2 = CB + 4 in. MERV 13, CCF
N = EQP, ULL, 2 in. MERV 13
b
Q = EQP, ULL, 4 in. MERV 13
b
R = EQP, 2 in. MERV 8
S = EQP, 2 in. MERV 13
T = EQP, 4 in. MERV 13
WD = 2-Stage Size 24-70 (compact)
WD = 1-Stage Size 07-18 (high efficiency)
Side Filter
Access
Bottom Filter
Access
Side Filter
Access
CT ECM
G
H
J
K
L
M
2-Way Valve (VLV)
E = EQP, ULL, 2 in. MERV 8
b
HWG — Hot Water Generator
SCCR — Short Circuit Current Rating
Refrigerant Circuit Options (11)
OPTION
None
A
B
Hot Gas Reheat
(HGRH)
a
C
D
Cooling Only (CO)
E
F
Hot Gas Bypass
(HGBP)
G
H
HGRH + HGBP
a
N
P
Hot Water
Generator (HWG)
Modulating Hot Gas
Reheat (MHGRH)
S
1
2
T
NON-COATED
AIR COIL
COATED
AIR COIL