Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-52480530-01 Printed in U.S.A. Form No. 48QE-17-28-01SI Rev A Pg 1 3-25 Replaces: New
Installation Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Rated Indoor Airflow (cfm) . . . . . . . . . . . . . . . . . . . . . 3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Job-Site Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Step 1 — Plan for Unit Location . . . . . . . . . . . . . . . 15
ROOF MOUNT
Step 2 — Plan for Sequence of Unit Installation . . 15
CURB-MOUNTED INSTALLATION
PAD-MOUNTED INSTALLATION
FRAME-MOUNTED INSTALLATION
Step 3 — Inspect Unit . . . . . . . . . . . . . . . . . . . . . . . . 15
Step 4 — Provide Unit Support . . . . . . . . . . . . . . . . 15
ROOF CURB MOUNT
SLAB MOUNT (HORIZONTAL UNITS ONLY)
ALTERNATE UNIT SUPPORT (IN LIEU OF CURB
MOUNT)
Step 5 — Field Fabricate Ductwork . . . . . . . . . . . . . 19
Step 6 — Rig and Place Unit . . . . . . . . . . . . . . . . . . 19
POSITIONING ON CURB
Step 7 — Horizontal Duct Connection . . . . . . . . . . 20
Step 8 — Install Outside Air Hood
(Factory Option) . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Step 9 — Assemble Barometric Hood . . . . . . . . . . 21
BAROMETRIC HOOD (VERTICAL CONFIGURATION)
BAROMETRIC HOOD (HORIZONTAL
CONFIGURATION)
Step 10 — Install Combustion Air Hood . . . . . . . . . 23
Step 11 — Install Flue Discharge Deflector . . . . . . 23
INSTALLATION
•SERVICE
Step 12 — Install Gas Piping . . . . . . . . . . . . . . . . . . 25
GAS SUPPLY LINE
FACTORY OPTION THRU-BASE CONNECTIONS
Step 13 — Install External Condensate
Trap and Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Step 14 — Make Electrical Connections . . . . . . . . . 27
FIELD POWER SUPPLY
UNITS WITHOUT FACTORY-INSTALLED
NON-FUSED DISCONNECT OR HACR
UNITS WITH FACTORY-INSTALLED NON-FUSED
DISCONNECT OR HACR
ALL UNITS
CONVENIENCE OUTLETS
FACTORY-OPTION THRU-BASE CONNECTIONS
FIELD CONTROL WIRING
THERMOSTAT
ZS SPACE SENSOR
Typical Unit Wiring Diagrams . . . . . . . . . . . . . . . . . .32
Integrated Gas Controller . . . . . . . . . . . . . . . . . . . . .36
Leak Dissipation System . . . . . . . . . . . . . . . . . . . . .39
SEQUENCE OF OPERATION
LEAK DISSIPATION SYSTEM SELF-TEST
TROUBLESHOOTING
SystemVu™ Controller . . . . . . . . . . . . . . . . . . . . . . .42
Step 15 — Adjust Factory-Installed Options . . . . . .42
SMOKE DETECTORS
Step 16 — Install Accessories . . . . . . . . . . . . . . . . .42
Step 17 — Fan Speed Set Up . . . . . . . . . . . . . . . . . .42
COMPRESSOR ROTATION . . . . . . . . . . . . . . . . . . . .44
PRESSURE RELIEF VALVES . . . . . . . . . . . . . . . . . .44
FASTENER TORQUE VALUES . . . . . . . . . . . . . . . . .45
TYPICAL UNIT PIPING . . . . . . . . . . . . . . . . . . . . . . . .45
TEMPORARY FURNACE OPERATION DURING
CONSTRUCTION . . . . . . . . . . . . . . . . . . . . . . . . . .48
START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . . CL-1
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can be
hazardous due to system pressure and electrical components. Only
trained and qualified service personnel should install, repair, or
service air-conditioning equipment.
Untrained personnel can perform basic maintenance functions of
cleaning coils and filters and replacing filters. All other operations
should be performed by trained service personnel. When working
on air-conditioning equipment, observe precautions in the
literature, tags and labels attached to the unit, and other safety
precautions that may apply.
Follow all safety codes, including ANSI (American National
Standards Institute) Z223.1. Wear safety glasses and work gloves.
Use quenching cloth for unbrazing operations. Have fire
extinguisher available for all brazing operations.
It is important to recognize safety information. This is the safety-
alert symbol . When you see this symbol on the unit and in
instructions or manuals, be alert to the potential for personal
injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices, which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.
WeatherMaster
®
Hybrid Heat 48QE**17-28
Single Package Rooftop Heat Pump with Gas Heat
with Puron Advance
(R-454B) Refrigerant
and EcoBlue
Fan Technology