8. Position both pieces of shrink-tubing so any portion of the cable without an outer insulation layer is covered.
9. Using a heat gun, apply even heat over the length and diameter of the tubing (minimum temperature 100° C).
IMPORTANT: Since uncontrolled heat can cause uneven shrinkage, physical damage, and insulation failure, the use of
open flame is not recommended. Avoid overheating the heat shrink-tubing because it can become brittle
and/or charred.
10. Gently push the headset connector cable back into the unit.
11. Align the rib on the headset connector with the notch in the connector opening and press the connector
completely in.
12. While holding the connector in place, turn the set screw clockwise to tighten the connector in position.
Bekijk gratis de handleiding van RTS EKP-3016, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.