NO
Disconnect the yellow wire
at the controller from the
black wire at the sensor.
Fill Valve Will Not Turn OFF
Sensor
is bad.
Is the Fill light on?
YES
Disconnect the yellow/blue wire
at the controller from the
red wire at the sensor.
Twist the yellow wire and the
yellow/blue wire together.
Does the fill
light turn off?
NO
PCB is bad.
YES
Does valve shut
off in 20 seconds?
NO
YES
NO
Possible Causes
1. Manual lever is on.
2. Diaphragm needs cleaning.
3. Diaphragm is bad.
4. Valve is bad.
Measure the voltage across the
blue wires with an AC volt meter.
YES
PCB is bad.
Relay is stuck.
Does the voltage
measure 24VAC?
Disconnect the blue wires
from the controller.
Disconnect the yellow wire
at the controller from the
black wire at the sensor.
Disconnect the yellow/blue wire
at the controller from the
white wire at the sensor.
Twist the yellow wire and the
yellow/blue wire together.
Does the valve shut
off in 20 seconds?
YES
Remove upper face plate to
check Fill LED.
NO
YES
Fix problem by aligning the
LED with the lens.
PCB or LED
is bad.
NO
Is LED on, but not
showing through lens?
5.3 Fill Valve Will Not Turn OFF
Page 18
ENGLISH
Jandy Pro Series Levolor
®
II Electronic Water Leveler
Models K-2000
|
Installation and Operation Manual