Fill Valve Will Not Turn ON
YES
Is power light on?
NO
Are long sensor
probes in water?
Is sensor light on?
Is fill light on?
What color
is light?
YES
YES
NO
NO
System is normal. Fill will not
turn on when water is full.
Check power to box.
- Circuit breaker
- Line voltage
- Wire connections to box
- Transformer voltage wiring
Disconnect red and black
sensor wires from
control box.
Does sensor
light turn on?
NO
PCB is bad.
Does fill light turn
on in 20 seconds?
NO
YES
YES
Green
Is there 24VAC
at blue wires
in control box?
NO
YES
Voltage is delivered to valve.
- If gate is closed, open it.
- If solenoid port is dirty, clean it.
- If solenoid is not working, replace it.
- If valve is clogged, clean it.
- If diaphragm is stuck, clean it.
- If diaphragm is bad, replace it.
Is there 24VAC
at valve?
NO
NO
Cable to valve is bad.
YES
24 Hour Lockout is in Effect.
- Check time to refill.
- Check valve operation.
- Check water supply.
- Check strainer.
Red
YES
5.4 Fill Valve Will Not Turn ON
Page 19
ENGLISH
Jandy Pro Series Levolor
®
II Electronic Water Leveler
Models K-2000
|
Installation and Operation Manual

Bekijk gratis de handleiding van JANDY Levolor K-2000, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkJANDY
ModelLevolor K-2000
CategorieNiet gecategoriseerd
TaalNederlands
Grootte2855 MB