Quick Start Guide
Use this template to drill holes for mounting the power pack
Important Safety Information
H0516300 REVC
Corona Discharge
Ozone Generator
CD40 CD70 CD100
WARNING
ELECTRIC SHOCK HAZARD
- Be sure to turn OFF and disconnect from power source before any routine maintenance is performed. Failure to do
so could result in serious injury or death.
- Install at least 5 feet (1.5 meters) from wall of pool using nonmetallic tubing. Install ozone generator no less than
one (1) foot above maximum water level to prevent water from contacting electrical equipment. Install in accordance
with the installation instructions.
- A pressure wire connector is provided on the outside of the unit, marked with “Bonding Lugs” to permit connection
to a minimum No. 6 AWG (13.3 mm
2
) solid bonding conductor between this point and any metal equipment, metal
enclosures of electrical equipment, metal water pipes, or conduit within fi ve (5) feet (1.5m) of the unit or as needed
to comply with local requirements.
- The Jandy
®
Pro Series Ozone generator must be installed in an outdoor location, or indoors in a forced air
ventilated room, and installed so that the orientation is exactly as shown in Figure 1. Install to provide water drainage
of generator to protect electrical components.
- Mount the Jandy Pro Series Ozone generator so that it is inaccessible to anyone in the pool, at least fi ve (5) feet
above ground height, and adequately outside of the direct path of sprinklers. Never attempt any servicing while unit
is wet.
- Plastic ozone supply tubing is supplied with the Jandy Pro Series Ozone generator. Never replace this tubing with
metal tubing.
- A green-colored terminal or a terminal marked G, GR, Ground, Grounding, or the symbol is located inside the
supply terminal box or compartment. To reduce the risk of electric shock, this terminal must be connected to the
grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the
circuit conductors supplying this equipment.
WARNING
If the Jandy Pro Series Ozone generator electrical connection is to be attached to the pool controls, be sure the
pool controls are protected by a Ground Fault Circuit Interrupter (G.F.C.I.). If the Jandy Pro Series Ozone generator
is connected to an independent electrical supply, then a G.F.C.I. must be installed between the Jandy Pro Series
Ozone generator and the electrical supply. Refer to local codes for complete details.
WARNING
Short-term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone can
cause serious harmful physiological effects. DO NOT inhale ozone gas produced by this device.Do not install this
product indoors.
Top Right
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualifi ed in pool
equipment by the jurisdiction in which the product will be installed where such state or local requirements exist, the
maintainer must be a professional with suffi cient experience in pool equipment installation and maintenance so that
all of the instructions in this installation guide AND the complete installation and operation manual accompanying the
product can be followed exactly. Before installing this product, read and follow all warning notices and instructions that
accompany this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty. Improper installation and/or operation can
create unwanted electrical hazard which can cause serious injury, property damage, or death. Turn off all circuit breakers
required in order to prevent the possibility of electric shock.
WARNING
Do not store or use gasoline, chemicals or other fl ammable liquids or vapors near this or any other appliance.
Parts & Tools Required
Power Requirements
MODEL
NUMBER
RATED VOLTAGE
RANGE
MAX
CURRENT
POWER
FREQUENCY
CD40 120-240 VAC 0.17A 50-60 Hz
CD70 120-240 VAC 0.29A 50-60 Hz
CD100 120-240 VAC 0.40A 50-60 Hz
Location Requirements
The generator must be mounted (as follows):
In a clean, protected area either indoors or outdoors (preferably
out of direct sunlight) an ideal ambient temperature between
32°F - 120°F (0°C - 50°C). (Indoor installations must be in a
forced air ventilated room.)
Out of reach of sprinklers or drainage spouts.
With suffi cient access for maintenance, all tubing, and
electrical wires.
At least (not less than) one foot above the maximum water level.
So that the bottom of the enclosure is at least three (3) feet
above ground and such that the center of the enclosure is no
more than six (6) feet above ground.
Water Chemistry
Adjust water chemistry to within the following guidelines:
pH: 7.4 - 7.6
Total Alkalinity: 80 - 120 ppm
Free Chlorine: 1.0 - 3.0 ppm
Combined Chlorine (Chloramines): None (superchlorinate
to remove all chloramines)
Chlorine Stabilizer (Cyanuric Acid): 30 - 50 ppm
Calcium Hardess: 200 - 400 ppm
Metals (Iron, Manganese): None
Nitrates: None
Phosphates: None
Top Left
Ozone Generator Mounting Template
Parts:
Ozone Generator
Ozone Tubing
Pipe Cap (3/4)
Flow Meter Assembly
Check Valve
Tube Adapter
Tube Clamps
Injector Manifold Assembly OR
Mixing Degas Vessel (MDV)
Mounting Screws (3), size 0.25
in. (6.3 mm), with anchors
(NOT INCLUDED. Choose
appropriate hardware
for the mounting surface.)
Tools:
Phillips Screwdriver
Scissors to cut tubing