JANDY Levolor K-2000 handleiding
Handleiding
Je bekijkt pagina 17 van 20

5.2.3 Simulate Water Level Full
Shut off the ll valve by simulating a water level full
condition.
1. Twist these three (3) wires together: yellow wire,
yellow wire with blue stripe, and yellow wire with
red stripe.
2. The Sensor light turns off immediately.
3. After 20 seconds, the Fill light turns off.
4. You can measure 0VAC across the blue wires with
an AC volt meter.
5.2.4 Simulate Lowering of High Water
Level in Catch Basin
Shut off the High Water Pump by simulating that the
High Water level in the vanishing edge catch basin has
lowered.
1. Disconnect the yellow wire with the red stripe
from the yellow wire and yellow wire with the
blue stripe.
2. The High Water Sensor light turns off
immediately.
3. After 20 seconds, the High Water Pump light
turns off.
4. You can measure 0VDC across the red and gray
wires with a DC volt meter.
5.2.5 Manual Valve Override
There is a manual ON/OFF lever located just below the
solenoid. If you are having a problem with the system
and want to override the electronic water Levolor, you
can manually open the valve by putting the lever in the
up position ↑ (12 o’clock) for manual lling. See
Figure 6, Manual Valve Lever, on page 9.
During normal operation, the lever must be in the
horizontal position → (3 o’clock) for controller lling.
See Figure 6, Manual Valve Lever, on page 9.
5.2.6 TroubleshootingSpecicConditions
Use the troubleshooting ow charts on the following
pages to nd and x the following problems.
- Fill Will Not Turn Off
- Fill Will Not Turn On
5.2.2 Simulate Fill Valve and Activate
Pump
NOTE Youhavesimulatedalowwaterconditionby
followingStep2.b.inSection 5.2.1.
1. Twist the yellow wire and the yellow wire with
the red stripe together to simulate a high water
condition in the vanishing edge catch basin.
2. Remove the three (3) screws from the upper cover
plate and lift the upper cover plate off the control
box.
3. Verify that dip switches S2-S10 are set to the OFF
position and that dip switch S1 is set to ON. See
Figure 14, page 15.
4. Verify that jumpers 1 and 2 are installed on the
control PCB. See Figure 13, page 14.
5. Replace the upper cover plate, making sure that
the ve (5) LEDs line up with the plastic lenses
on the cover. Attach the upper cover plate to the
control box using three (3) screws. Do not over
tighten.
6. Restore power to the control box and observe the
operation. The control box is working if steps
6 a - e and the steps in Section 5.2.3 and
Section 5.2.4 occur.
a. The Power light turns green.
b. The Sensor light turns yellow.
c. The High Water Sensor light turns yellow.
d. After 20 seconds, the Fill light turns green
and you can measure 24VAC across the blue
wires with an AC volt meter.
e. After 2 ½ minutes, the High Water Pump
light turns green and you can measure
24VDC across the red and gray wires with a
DC volt meter.
Page 17
ENGLISH
Jandy Pro Series Levolor
®
II Electronic Water Leveler
Models K-2000
|
Installation and Operation Manual
Bekijk gratis de handleiding van JANDY Levolor K-2000, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | JANDY |
Model | Levolor K-2000 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 2855 MB |