Pro Series Ozone Generator
6. Turn on electrical power.
7. Turn on the pump.
8. Verify that the metal ball in the ow meter assembly oats
between the Max and Min lines (Figure 10).
MAX
MIN
Figure 10. Ideal Ozone Flow Reading
9. If ozone gas ow is too low, verify that other valves in the system
are not inhibiting ow through the manifold.
NOTE: The manifold injector comes equipped with a spring-loaded valve
to provide a wide operating range and is not adjustable. For
additional complications related to ozone gas ow, see Section 6.
Troubleshooting.
10. Remove the ow meter assembly from the ozone outlet barb
and from the ozone tube. Store the ow meter tubing inside the
ozone generator housing for future use.
11. Cut off any excess tubing so that the line from the injector
manifold to the ozone generator is straight and free from dips
and loops.
12. Connect the end of the ozone tube to the ozone outlet barb.
Ensure that all hose barb connections are secured with hose
clamps. Secure and route any slack tubing as necessary, to
minimize tripping or entanglement hazard.