Pro Series Ozone Generator
Vertical Installation: The ozone check valve must be above the
injector port. Ensure the hose is cut for as little slack as possible so
that water does not collect in the hose (see Figure 5).
Horizontal Installation (with ozone check valve down): Ozone
check valve may stick open or shut causing premature wearing of
the check valve (see Figure 5).
NOTE: The injector manifold should be installed above water level whenever
possible. If the injector manifold is installed below water level, take proper
precautions to prevent water from draining through the injector and
damaging the surrounding area. For example, use clamps on all tube
connections, run ozone tubing above water level and provide adequate
drainage around the pool equipment.
Check Valve
Check Valve
Check Valve
Check Valve
Check Valve
Check Valve
Figure 5. Correct Ozone Check Valve Installation in Alternate
Orientation