When the “Use the same measurement device next time” checkbox is selected, the currently selected
measurement device will be automatically selected the next time.
5.
To use an external measurement device, install the measurement device on the
measurement window.
The installation method varies by the measurement device. For details, refer to the User's Manual of
the respective measurement device.
Attention
Depending on the settings of the monitor and the OS, the measurement window may not appear in the center
of the screen. If that happens, install the measurement device close to the center of the monitor regardless of
where the measurement window is located.
Measurement device used by being in contact with the monitor
Tilt the monitor panel surface slightly upward and install the measurement device to the measurement
window.
Calibrating CG3145 / CG3146 / CG1
Install the measurement device on a tripod or a similar xing base, and place it approximately 5 cm to
20 cm away from the panel surface.
Attention
If the measurement is taken while the monitor is in contact with the panel, the results will not turn out to be
accurate due to the accumulated heat.