5.2Solvingdevicemalfunctions
Dysfunction Causes Verification/solution
Thedeviceisnot
operational
Nodisplay CheckthesupplyvoltageandthefuseF1
Thepooltemperatureisabovethe
setpointtemperature
Increasethesetpointtemperature
Amessageisdisplayedonthescreen Checkthemeaningofmessage§5.1
Absentorinadequatewaterflowrate Checkthewaterflowrate(bypass,filtration)
Thedeviceis
operational,butwater
temperaturefailsto
rise
Inadequatefilteringtime
Setthefilteringsystemtomanual24‐hour
operationfortemperaturecontrol
Noncompliantperiodofuse
Checkthatoutdoortemp eratureiswithinthe
operatingrange(see§1.3)
Theheatpumpisunderdimensioned
Checkthecharacteristicsoftheheatpump
accordingtothepool
Theautomaticpoolwaterfilleris
blockedintheopenposition
Checkthecorrectoperationoftheautomatic
filler
Theheatinsulatingcoverisnotused Fittheheatinsulatingcover
Theevaporatorisclogged Cleantheevaporator(see§4.1)
Thedeviceisincorrectlyinstalled
Thedevicemustbeinstalledoutdoors.
Checkthatthereisnoobstaclelessthan 4
metresfromwheretheblowerisfacing,and
0.50metresbehindtheheatpump.
Amessageisdisplayedonthescreen Checkthemeaningofmessage§5.1
Thefanisturning,but
thecompressorstops
fromtimetotime
withoutanerror
messageappearing
Theheatpumpdoesdefrostcycles
fromtimetotime
Thisisnormaliftheoutdoortemperatureis
below10°C
Theevaporatorisclogged Cleantheevaporator(see§4.1)
theheatpumpmakes
tripthecircuitbreaker
Thecircuitbreakerratingistoolowor
inappropriate
Checkthecircuitbreaker(see§2.5.3).
Thecablecrosssectionistoosmall Checkthecablecrosssection(see§2.5.3)
Thesupplyvoltageistoolow Callyourelectricityprovider
Voltagedropswhenthecompressor
ispoweredon
AddasoftstarterformodelsM5,MD5and
M7
Varistor(s)VA1and/orVA2is/areout
oforder
Replacethevaristor(s)
5.3FAQ
Isitpossibleto
improve
temperature
performance?
Inorderto
improvethe
efficiencyof
yourheat
pumpitis
recommended
thatyou:
protectthepoolwithacover(floatingcover,rollercover,etc.),toavoidheat
loss
chooseperiodswhentheoutsidetemperatureiswarm(onaverage>10°C)
inordertofacilitate thetemperature increase (thismaytake several days.
Theactualtimewillvaryaccordingtoweatherconditionsandthepowerof
theheatpump)
thehigherthe ambient air temperature, the more efficient the heat pu mp
willbe
keeptheevaporatorclean
Checkthat
filtrationtime
issufficient
duringtheheatingphase,waterflowmustbecontinuous(24/24)
tomaintainthetemperaturethroughouttheseason,allowfor“automatic”
flowofatleast 12hours/day(thelongerautomaticflowis used, the more
timetheheatpumpwillhavetofunctionandtoheatthewater)
Settingthesetpointtomaximumwillnotheatthewateranyfaster