H0439100.A1.EN2013/10 13
Whyismyheat
pumpnotheating?
on startup the device remains on “pause” for 3 minutes before actually starting up:
checkthatthisperiodhaspassed
oncethepoolhasreached thesetpointtemperature,theheatpumpswitchesoff:check
thatthewatertemperatureislowerthantherequestedtemperature(see§3.2)
ifthewaterflowrateiszeroorinadequate,theheatpumpwillstop:checkthatwateris
flowingcorrectlythroughtheheatpump,andcheckthehydraulicconnections
whentheoutdoorairtemperaturedropsbelow5or‐8°C,theheatpumpwillstop:check
theoutdoortemperature
theheatpumpmayhavedetectedamalfunction:checkifanerrorcodeisdisplayedon
thescreen,ifsoreferto§5.1
If the problem persists after you have checked all of the above points: cont act your
installer
Whereshouldmy
watertreatment
systembe
positionedwith
respecttothe
heatingsystem?
The water treatment system (chlorinator, salt chlorinator, etc.) must be installed
preferably downstream from the heat pump (see installation §2.4), and must be
compatiblewiththelatter(checkwiththemanufacturer)
Theheatpumpis
givingoffwater:is
thisnormal?
Your heat pump will give off water in the form of condensation. This water is the
humiditycontainedintheair,whichcondensesoncontactwithcertaincoldcomponents
insidetheheatpump.
Note:yourdevicecanproduceseverallitresofwaterperday.
6.Productregistration
Registeryourproductusingourwebsite:
- youwillbeamongthefirsttobeinformedofnewZodiacproductsandspecialoffers,
- Youcanhelpustoconstantlyimproveourproductquality.
AustraliaNewZealand www.zodiac.com.au
Europe,SouthAfricaandrestoftheworld www.zodiacpoolcare.com

Bekijk gratis de handleiding van Zodiac Z300 M7, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkZodiac
ModelZ300 M7
CategorieNiet gecategoriseerd
TaalNederlands
Grootte8547 MB