15
Display of Possible causes Soluons Reseng
ST5 sensor error
compressor discharge
sensor
Sensor is faulty or oine (J7-A1
connector)
Reconnect or change the sensor
By electricity
supply
disconnecon or
automac if the
fault disappears
Communicaon
fault between the
regulaon board and
the display board
Bad connecon between the A1
and A2 boards
Check the J8, J9, J7 and J4-
J5 connectors on the link cable
between the boards
By electricity
supply
disconnecon or
automac if the
fault disappears
Board power supply fault
Check the boards' power supply
Faulty boards
Replace the boards
Venlaon command
fault
Lack of informaon on the fan
speed
Call an approved technician
Cut power or press
Communicaon fault
with the A3 venlaon
board
Poor connecons
Check the connecons
By electricity
supply
disconnecon or
automac if the
fault disappears
Power supply fault
Check the power supply
Incorrect conguraon
Check the posion of switches
SW1 and SW2 and the JPC bridge
Board out of service
Replace the board
4.3 I Addional menus
To access the menu, press .
To browse the menus and modify the values, press or
To exit the menu, press .
You may consult the latest faults:
You may read the values measured by the sensors and the operaon of the electronic valve and the fan.
Water temperature on intake
Air temperature
Defrost sensor
Fluid line sensor
Compressor discharge temperature
Opening of electronic valve
Fan operang speed