Zodiac Power Force handleiding

128 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 33 van 128
14
4.2 I Error code display
Display Possible causes Soluons Reseng
Exchanger protecon
in cool mode
ST4 sensor temperature too low
Wait unl the exterior temperature
rises
Automac
High temperature
error on evaporator in
"cooling" mode
ST3 sensor temperature over
60°C or evaporator scaled up
Clean the evaporator, if problem
persists, call an approved technician
Automac if
ST3 sensor
temperature below
450C
Phase order fault
Cabling not respected on the
appliance's supply terminals,
Invert phases on power terminals
(appliance switched o )
By electricity
supply
disconnecon or
by pressing
Electricity provider has changed
the order of the phases
Contact the electricity provided to
nd out if your installaon has been
modied.
Temporary disconnecon of the
power supply to one or more
phases
Low pressure fault on
cooling circuit
Pressure fault in the low
pressure circuit (if problem
persists aer reseng)
Call an approved technician
Automac (if fewer
than 4 faults per
hour) or press
Cooling circuit high
pressure fault
Water condenser scaled up
Clean the water condenser
Automac (if fewer
than 4 faults per
hour) or press
Insucient water ow
Increase ow using by-pass, check
that the pool lter is not clogged
Air and water emulsion passed
into the device
Check the pool's hydraulic circuit
Flow controller blocked
Check the ow controller
Compressor discharge
temperature fault
Compressor discharge
temperature too high
Call an approved technician
Press
for 3
seconds
ST1 sensor fault
water intake sensor
Sensor is faulty or oine
(J12-A1 connector)
Reconnect or change the sensor
Cut power or press
ST4 sensor fault uid
line sensor
Sensor is faulty or oine (J8-A1
connector)
Reconnect or change the sensor
By electricity
supply
disconnecon or
automac if the
fault disappears
ST3 sensor fault
Defrost sensor
Sensor is faulty or oine
(terminals 1-2 connector J3-A2)
Reconnect or change the sensor
Cut power or press
ST sensor fault air
intake sensor
Sensor is faulty or oine
(terminals 3-4 connector J3-A2)
Reconnect or change the sensor
Cut power or press

Bekijk gratis de handleiding van Zodiac Power Force, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkZodiac
ModelPower Force
CategorieNiet gecategoriseerd
TaalNederlands
Grootte28463 MB