Zodiac Power Force handleiding
Handleiding
Je bekijkt pagina 33 van 128

14
4.2 I Error code display
Display Possible causes Soluons Reseng
Exchanger protecon
in cool mode
ST4 sensor temperature too low
Wait unl the exterior temperature
rises
Automac
High temperature
error on evaporator in
"cooling" mode
ST3 sensor temperature over
60°C or evaporator scaled up
Clean the evaporator, if problem
persists, call an approved technician
Automac if
ST3 sensor
temperature below
450C
Phase order fault
Cabling not respected on the
appliance's supply terminals,
Invert phases on power terminals
(appliance switched o )
By electricity
supply
disconnecon or
by pressing
Electricity provider has changed
the order of the phases
Contact the electricity provided to
nd out if your installaon has been
modied.
Temporary disconnecon of the
power supply to one or more
phases
Low pressure fault on
cooling circuit
Pressure fault in the low
pressure circuit (if problem
persists aer reseng)
Call an approved technician
Automac (if fewer
than 4 faults per
hour) or press
Cooling circuit high
pressure fault
Water condenser scaled up
Clean the water condenser
Automac (if fewer
than 4 faults per
hour) or press
Insucient water ow
Increase ow using by-pass, check
that the pool lter is not clogged
Air and water emulsion passed
into the device
Check the pool's hydraulic circuit
Flow controller blocked
Check the ow controller
Compressor discharge
temperature fault
Compressor discharge
temperature too high
Call an approved technician
Press
for 3
seconds
ST1 sensor fault
water intake sensor
Sensor is faulty or oine
(J12-A1 connector)
Reconnect or change the sensor
Cut power or press
ST4 sensor fault uid
line sensor
Sensor is faulty or oine (J8-A1
connector)
Reconnect or change the sensor
By electricity
supply
disconnecon or
automac if the
fault disappears
ST3 sensor fault
Defrost sensor
Sensor is faulty or oine
(terminals 1-2 connector J3-A2)
Reconnect or change the sensor
Cut power or press
ST sensor fault air
intake sensor
Sensor is faulty or oine
(terminals 3-4 connector J3-A2)
Reconnect or change the sensor
Cut power or press