37
PM40 mers
Heang Priority
mode
Setpoint not reached
(water temperature < desired
temperature)
Setpoint reached
(water temperature >
desired temperature)
(start me = end
me)
(F09 = 1)
• Heat pump on
• Filter pump on
• Heat pump o
• Filtraon on, depending on the lter
pump's mer (or acvated for 5 minutes
every 2 hours if the lter pump is outside
of its normal operang mes)
(F09 = 0)
• Heat pump on
• Filter pump on
• Heat pump o
• Filter pump on connuously 24/7 (no
operang me restricons from the heat
pump clock)
(start me ≠ end
me)
During the
scheduled
operang mes
(F09 = 1)
• Heat pump on
• Filter pump on
• Heat pump o
• Filtraon on, depending on the lter
pump's mer (or acvated for 5 minutes
every 2 hours if the lter pump is outside
of its normal operang mes)
(F09 = 0)
• Heat pump o
• Filter pump on during the scheduled
operang mes set by the heat pump's
mer
(start me ≠ end
me)
Outside of
the scheduled
operang mes
(F09 = 1)
• Heat pump o
• Filter pump o, regardless of the water temperature (heat pump clock
prohibits operaon)
(F09 = 0)
: Enabled
: Disabled