Zodiac HPO handleiding

28 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 13 van 28
12
Reduce the temperature setpoint to below the water temperature to check that the heat pump stops operang.
Switch o the heat pump by pressing and check that it stops.
2.4 I User funcons
2.4.1 "Automac keypad lock" funcon
The "automac keypad lock" funcon allows the keypad to be disabled when inacve for a certain period of me to
prevent mishandling.
Locking/unlocking the keypad:
Press + simultaneously for 5 seconds.
The indicator appears (= locked) or disappears (= unlocked) depending on the keypad's state.
2.4.2 Changing operang mode
The heat pump can operate in "HEATING", "COOLING" or "HEATING & COOLING" (automac regulaon) mode.
Informaon: "HEATING" mode
When "HEATING" mode is selected, the heat pump heats the pool water to the temperature setpoint.
The heat pump stops automacally once the temperature setpoint is reached.
Informaon: "COOLING" mode
When "COOLING" mode is selected, the heat pump cools the pool water to the temperature setpoint.
The heat pump stops automacally once the temperature setpoint is reached.
Informaon: "HEATING & COOLING" mode (automac regulaon)
When the "HEATING & COOLING" operang mode is selected, the heat pump automacally switches to
"HEATING" mode (if the water temperature falls -1°C below the temperature setpoint) or to "COOLING"
mode (if the water temperature rises +2°C above the temperature setpoint) in order to maintain the
pool at the temperature setpoint.
Example: When the temperature setpoint is 28°C, if the water temperature rises to 30°C, the heat
pump will automacally switch to "COOLING" mode to return to the temperature setpoint. If the water
temperature falls to 27 °C, the heat pump will automacally switch to "HEATING" mode to return to the
temperature setpoint.
To switch to "HEATING", "COOLING" or "HEATING & COOLING" (automac control) mode:
Press for 5 seconds to select "HEATING", "COOLING" or "HEATING & COOLING" (automac regulaon) mode.
The corresponding indicator lights up to indicate the mode selected.
In "HEATING & COOLING" mode (automac regulaon), the 2 indicators and are lit.
2.4.3 Conguring the temperature setpoint
Begin by selecng the desired operang mode: "HEATING" , "COOLING" or "HEATING & COOLING" (automac
regulaon) using the key.
Press or , the setpoint value of the previously selected operang mode will ash.
Press to increase the temperature by 1°C,
Press to reduce the temperature by 1°C.
Press to conrm and exit "conguraon" mode.
EN

Bekijk gratis de handleiding van Zodiac HPO, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkZodiac
ModelHPO
CategorieNiet gecategoriseerd
TaalNederlands
Grootte6991 MB