2.4.4 "BOOST", "SMART" and "SILENCE" mode
The heat pump can adapt its power to suit the pool temperature and weather condions. In doing so, it obtains maximal
energy eciency at a very low noise level.
Silence
Boost
"BOOST" mode "SMART" mode "SILENCE" mode
Compressor operang
speed*
HIGH
MID
LOW
Operang
principle
The heat pump operates at full
power.
The heat pump operates
intelligently, at medium to high
speeds.
The heat pump operates at low
power for lower consumpon
and less noise.
Adapts the power automacally to requirements.
When to use
Heang: when commissioning
the pool.
To maintain the temperature
When you don't want to handle
the appliance
Low heang requirements and
silent operaon desired
Cooling: hot zones, heat waves,
sheltered pools, etc.
* The compressor speed directly aects the appliance's power output.
Press
BOOST
,
SMART
or
SILENCE
the indicator above the selected mode is lit.
Informaon: "SMART" mode
When the heat pump is operang at full power in "SMART" mode, the "SMART" indicator light is lit and
the "BOOST" indicator light ashes.
Informaon: "SILENCE" mode
When the heat pump is operang at medium power in "SILENCE" mode, the "SILENCE" indicator light is
lit and the "SMART" indicator light ashes.
2.4.5 Conguring the "TIMER"
Press then to view the "mer acvaon" ("P2"), "on me" ("P5") and "o me" ("P6") sengs for the
"TIMER".
Sengs Meaning Amplitude Default seng Comments
P2 Timer acvaon 0 - 1 0
0 = mer disabled
1 = mer enabled
P5 On me HH: MM 00: 00 0-23: 0-59
P6 O me HH: MM 00: 00 0-23: 0-59