9
❸ Use
Never run the circulang pump (depending on the model) without water. The circulang
pump is very quiet when it starts up; you may not hear it running.
3.1 I Operang principle
The heat pump uses the calories (heat) from the home's heang to heat up the pool's water.
The heat is exchanged through a series of pipes: the home's heang water circulates through the exchanger's body and
the pool water circulates through the pipes.
Tips: improve the pool's temperature rise and maintenance
Cover the pool with a sheet (bubble canopy, canvas, etc.) to prevent heat loss. The closer the heat source
is to the exchanger, and the exchanger is to the pool, the less heat will be lost.
Ancipate the commissioning of your pool far enough in advance before you use it.
For the temperature rise, set the ltraon pump to connuous operaon (24/24).
To maintain the temperature throughout the season, run "automac" circulaon for at least
12 hours/day (the longer this me the longer the appliance will have enough operang range to heat up)
3.2 I User interface presentaon (depending on the model)
Display screen (default: water temperature measured)
"On/o" buon
Value seng buons
Steady Flashing O
"On/o"
“On/o
Appliance
powered up
/
No electrical
supply
Heang light
Heang in
progress
Timed before operaon
No water circulaon in the secondary
circuit (less than 1.1m³/h)
No need for
heang
Tips: using the user interface
The temperature is regulated by degrees.
Hold down the buons to scroll through the values quickly.
The setpoint adjustment range is between 2° and 40°C.
The maximum temperature may be lowered to protect the pool liner (see § 3.2.1 “Modifying the
maximum setpoint”).
3.2.1 Modifying the maximum setpoint
Switch o the regulator (the "ON" light goes o and the pool water temperature is displayed),
Press and simultaneously for 5 seconds: "PA" is displayed,
Press , then enter the value "80" with or (code to access the "Sengs" menu),
Press to conrm: "PA" is displayed,
Press and simultaneously for 5 seconds: "/1" is displayed,
Press to scroll through each parameter unl "r2" is displayed,
Press , the current "r2" parameter value is displayed,
Press or to modify the maximum setpoint value, then press to validate this new value,
Press the and keys at the same me for 5 seconds to return to the pool water temperature display.