3.3 I Operaon
• Never run the circulang pump (depending on the model) without water. The circulang
pump is very quiet when it starts up; you may not hear it running.
• Never run water through the primary circuit when there is no water running through the
secondary circuit.
• The ow rate must be adjusted slowly to avoid hammering.
: Pool water inlet valve (secondary circuit)
: Pool water bypass valve (secondary circuit)
: Pool water outlet valve (secondary circuit)
: Heang water inlet valve (primary circuit)
: Heang water outlet valve (primary circuit)
• Check that the hydraulic connecons are correctly ghtened and that there are no leaks.
• Check that the appliance is stable.
• Posion the valves as follows: valves A and C fully open, valve B closed.
• Start the ltraon pump.
• Check that the pool water is owing through the exchanger,
• Open valves D and E fully,
• Check that the heang circuit is lled and vented,
• Connect the regulaon to the power supply and turn it on,
• Adjust the temperature setpoint..
• Aer the start-up steps for your exchanger:
- Check that there are no leaks,
- Check that the circulang pump stops working in case the setpoint temperature is reduced, the regulaon is
stopped or the ltraon is stopped.
- Check that the exchanger is no longer irrigated with water by the heang circuit when the ltraon is stopped and
that there are no pool water heang requests.
Tip: Tips: choosing the regulaon module for a Bare Heat Line
• It must reference the input temperature of the pool water in the appliance.
• It must give the command to irrigate the primary circuit only if heang is requested and ltraon is
operaonal,
• It must stop irrigang the primary circuit once the pool has reached the desired temperature.
Tip: Restarng the circulang pump aer a long shutdown period
• In the event of a blockage, an indicator lights up (see § « 5.2 I Error code display »). In this case, use a
screwdriver to manually release the blockage through the central hole provided in the circulang pump.