5.3 I Calibra ng the sensors (if an op onal "pH Link" or "Dual Link" module has been installed)
5.3.1 Calibra ng the pH sensor (blue)
The pH sensor can be calibrated to 1 point or 2 points (pH 4 and pH 7). 2-point calibra on is recommended to improve
measurement accuracy.
The setpoints are displayed on the home screen when the appliance is switched on.
Current sensor measurements
Setpoints
• Switch on the appliance.
• Switch o the pool's pump and close the necessary valves in order to isolate the cell and the sensors.
• Press
and browse the menu using the bu ons. Press to con rm.
• Select 1- or 2-point calibra on (2-point calibra on is recommended):
• Unscrew and remove the pH sensor from the POD.
• Rinse the p of the sensor with tap water.
• Shake it to remove any residual water. Do not touch the glass bulb at the end of the pH sensor.
• Place the pH sensor in the pH 7 solu on and follow the on-screen instruc ons:
• Rinse the p of the sensor with tap water.
• Shake it to remove any residual water. Do not touch the glass bulb at the end of the pH sensor.
• Place the pH sensor in the pH 4 solu on and follow the on-screen instruc ons:
• Once calibra on is complete, replace the sensor on the POD.
• If calibra on is unsuccessful, see “8.1 I Appliance behaviour”.
1-point calibra on: possible if the pH 7 and pH 4 solu ons provided are no longer available.
In order to do this:
- Use a sample of water with a known pH value.
- Ac vate 1-point calibra on and input this pH value on the screen: