2.2 I Hydraulic connec� ons
2.2.1 Sensor and injec on point loca on
• The pH sensor must be installed more than 30 cm before or a� er a piping bend. Use the op onal
POD kit if necessary. Failing to follow this posi oning can lead to incorrect or unstable measure-
ments.
• The p of the pH sensor must not be in contact with the pipe.
• Never install a pH sensor before the ltra on pump or between the pump and the lter. This
would cause random readings and a shortened service life.
• The pH sensor must be placed a� er the lter and before the hea ng system,
• It must be placed ver cally or sloping at a maximum of 45°; it should never point downwards.
• The injec on point must be the last element on the pool circuit, a� er any hea ng and water treatment
systems.