7
2.1.2 Appliance injec on programme
Example of 4 cycles with a set point at 7.4 pH and acid regula on (standard alkalinity):
pH ≥ 7.55: 20% injec on (2 min) & 80% pause (8 min)
pH ≥ 7.7: 50% injec on (5 min) & 50 % pause (5 min)
pH ≥ 7.85: 75% injec on (7 min 30 sec) & 25% pause (2 min 30 sec)
pH < 7.9: 100% injec on (10 min)
The injec on programme is of course inverted when a basic dosage is selected.
Ac ve chlorine is more effi cient with the correct pH level.
Maximum release rate is 1.5 L/h. This dosage ensures that the set point is reached quickly and
accurately.
This propor onal injec on is cyclic and the cycle dura on is 10 minutes. The
dose will change according to the distribu on of injec on mes and pauses.
The propor onality adjusts automa cally and the balancing between the
di erent doses is made in 0.15 pH steps.
2.1.3 Adjus ng dosage according to alkalinity
The pH level of water is poten ally unstable. Its stability is governed by the level of water alkalinity (also called "TA" for
‘‘Total alkalinity’’). If the TA is low (< 100 ppm), the pH will become poten ally unstable and conversely if the TA is high
(>150 ppm).
In order to always achieve op mal water balance, the appliance has a feature that allows users to adjust the quan ty of
corrector product poten ally injected depending on the water TA (see §"3.5.4 "Dosage" menu")