❷ Installa� on
2.1 I Preparing the pool
2.1.1 Water balance
It is essen al that the pool water balance is controlled and adjusted before installing the appliance. Making
sure that the pool water balance is correct from the very start will reduce the likelihood of encountering
problems on the  rst days of opera on or during the season the pool is in use.
Even though it is an automa c regula on system, it is essen al to carry out regular water analyses
to check the water balance parameters.
Unit
Recommended
values
To increase To decrease
Test frequency
(during the
season)
pH
/ 7.2 – 7.4
Use the appliance in
"alkaline" dosage mode
and/or increase the set
point.
Use the appliance in
"acidic" dosage mode
and/or decrease the
set point.
Weekly
Free
chlorine
mg/L
or ppm
0.5 – 2
Add chlorine (manually
or using an automated
system)
Stop the release or
produc on of chlorine
Weekly
TA
(alkalinity
or bu er
capacity)
°f (ppm)
8 – 15
(80 – 150)
Add alkalinity corrector
(Alca+ or TA+)
Add hydrochloric acid Monthly
HL
(hardness
level)
°f (ppm)
10 – 30
(100 – 300)
Add calcium chloride
Add a scale
sequestering
agent or carry out
decarbona on
Monthly
Cyanuric
acid
(stabiliser)
mg/L
or ppm
< 30 /
Par ally empty the
pool and re ll it
Quarterly
Metals
(Cu, Fe,
Mn…)
mg/L
or ppm
± 0 /
Add a metal
sequestering agent
Quarterly