❺ Troubleshoo� ng
If a problem occurs, before you contact your retailer, please carry out these few simple checks
using the following tables.
If the problem con nues, contact your retailer.
: Ac� ons to be performed by a qualifi ed technician only
5.1 I Appliance behaviour
Behaviour Possible causes Solu ons
The value displayed
on the appliance is
frozen at about 7.0 pH
Cable problem and/or BNC
connector problem
Check that the connec on between the
sensor and the control box has not short cir-
cuited (between the cable's central core and the
external shielding)
Check that there is no dampness and/or
condensa on on the BNC socket
The appliance always
displays an unsuitable
or constantly unstable
value
The pH sensor connec on
cable is damaged
Check the cable and/or the BNC connector
The pH sensor cable is too
close to an electric cable lead-
ing to interference
Reduce the distance between the appliance
and the sensor
There is an air bubble in
the pH sensor bulb
Put the pH sensor in the ver cal posi on
and shake it gently so that the air bubble rises
to the top (it must be mounted in the ver cal
posi on or lted to 45° maximum, see §"2.2.1
Sensor and injec on point loca on")
Problem on sensor's porous
coa ng and/or dirt deposits
Restart calibra on
Check that the pH sensor bulb is not
damaged and that it did not dry outside the
water
As a last resort, clean it by dipping the
sensor in a 10% hydrochloric acid solu on for a
few hours
The sensor is not correctly
ed on the piping
Place the sensor in a more suitable loca on
(see §"2.2.1 Sensor and injec on point loca-
on")
Slow response from
the pH sensor
The pH sensor is electro-
sta cally charged
Rinse the sensor with clean water
Do not wipe the sensor with a cloth or
paper, shake it gently
EN