5.2 I Displays
Message Possible causes Solu ons
"Level Low"
Corrector product container
empty
Replace the corrector product container
Floater blocked Check that the white oater on the suc on
cane is in working order
Level sensor cut o Change the suc on cane
"OFA Alarm"
First step of the ac vated over
feed safety mechanism ( me >
75%)
Press
to stop the alarm
Check the sensor and/or the pH in the pool
"OFA Stop"
Second step of the ac vated
over feed safety mechanism
( me = 100%)
Press
to stop the alarm
Check the sensor and/or the pH in the pool
"OFA Test"
pH sensor measurement test if
the "OFA Stop" was ac vated
during the previous ltering
cycle
Wait for the end of the procedure (1 hour)
then check the sensor and/or the pool pH
level
"Filtering"
Filtering stopped Start and/or check the  ltering
Incorrect connec on Check the electrical connec ons
"4pH Sensor Fail"
or
7pH Sensor Fail"
Bu er solu on defec ve Check that the solu on used is pH7 or pH4
Take a new pH7 and/or pH4 bu er solu on
Check the pH of the bu er solu on with an
electronic pH meter
Problem on sensor's porous
coa ng and/or dirt deposits
Restart calibra on
Check that the pH sensor bulb is not
damaged and that it did not dry outside the
water
As a last resort, clean it by dipping the
sensor in a 10% hydrochloric acid solu on for a
few hours
Check that the sensor's porous coa ng is in
good condi on (wash the sensor with an acidic
solu on)
The sensor is worn Replace the pH sensor
The sensor is electrically
charged
Rinse the sensor with clean water
Do not wipe the sensor with a cloth or
paper, shake it gently
If the problem persists, replace the pH sensor
"Parameter Error"
Parameter error
Press
to cancel the error
Replace the printed circuit board
If the problem con nues, contact your retailer.