Zodiac GenPH handleiding

20 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 20
16
❹ Maintenance
4.1 I Changing the peristal� c tube
Remove the peristal c pump cover,
Place the roller holder at "10:20" by turning it clockwise,
Completely free the le� ng by keeping it stretched outwards,
Then turn the roller holder clockwise to free up the tube as far as the right  ng
Make sure that the roller holder is in the 10:20 posi on.
Insert the le� ng of the new peristal c tube into its housing.
Then pass the tube into the roller holder guide.
Turn the roller holder clockwise and accompany the tube as far as the right  ng.
Re t the peristal c pump cover.
4.2 I Winterizing
Always keep the sensor in water and frost-protected.
During winterising, it is recommended to leave the pump in clean water in order to
rinse the peristal c tube by carrying out manual priming (see §"3.4 I Priming the
peristal c pump").
Then place the roller holder at 6 o’clock to facilitate restar ng.
Remove the pH sensor from its holder and store it in its original bo le or in a container
lled with tap water.
Close o the sensor holder if necessary.

Bekijk gratis de handleiding van Zodiac GenPH, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkZodiac
ModelGenPH
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5404 MB