This appliance is ed with a safety mechanism to avoid any risk of correc on product overdose, for example
in the event of a problem with the sensor. This safety mechanism, called the "OFA" (= Over Feed Alarm),
pauses the appliance if it has not reached the set point within a given me limit. A high set point value is
strongly recommended to avoid any unplanned and/or unjus ed triggering (a  me of  ltra on in excess of
4 hours is recommended for large pools and/or pools or with high alkalinity levels).
The over feed safety mechanism operates in two main steps:
ashes a� er 75% of the programmed me has elapsed without having
reached the set point
is displayed when the me has elapsed. The appliance then switches to
safety mode.
If ltering stops and restarts while the appliance is in "OFA Stop" status, the appliance will ac vate an "OFA
Test" mode for 1 hour to make sure that the measurement from the sensor is correct.
On comple on of this "OFA Test" mode:
- if the set point has been reached = the appliance remains in normal mode
- if the set point has not been reached: the appliance switches to "OFA Alarm" mode and make an injec on
of corrector product
- if the set point has s ll not been reached a� er the "OFA Alarm" mode is complete (=25% of total OFA set
me), the appliance switches to "OFA Stop" (thus stopping any product injec on process) and safety mode
and will remain in this state un l manual interven on.
To reset this safety measure and restart the appliance, press the key. First make sure that the sensor is
in good condi on and is calibrated.
Special over feed safety func on:
In order to prevent false alarms just a� er the appliance is installed, the over feed safety can be deac vated
for 24 or 48 hours:
Press
, and at the same me to deac vate the safety mechanism for 24 hours
Press , and at the same me to deac vate the safety mechanism for 48 hours

It is possible to perform calibra on in a single step for pH7 (quicker but the measurements will be less reliable
in me), or to remove this func on (we advise strongly against this, except in the case of pools under a
maintenance contract).

This appliance is ed with a double electric power supply making it possible to keep the appliance switched on
to carry out pH sensor calibra on when ltering is not opera onal. This func on can however, be deac vated
in the case of a di erent electrical connec on (only carried out by a professional).
 



All factory se ngs can be restored.
Turn o the appliance
Turn the appliance back on by pressing and at the same  me:
Select "Yes" or "No" using the and keys, then con rm by pressing .
EN