2. Operating the pump
Allow the pump to run and monitor its progress.
Unplug the pump when it has removed water down to approximately 1/8 in.
(3.2 mm).
Remove the pump and hose from the location when finished pumping. The
hose still has water that can drain back through the pump. Remove
remaining water with a squeegee, mop, sponge, towel, wet/dry vac, etc.
CAUTION: Do not run the pump dry. Operating the pump without water will
cause damage to the seals and will cause the pump to fail, thereby voiding the
pump’s warranty.
NOTE: After starting, the pump will lower the water level to 1/8 in. (3.2 mm) before losing suction. It will not pick up
water less than 1/8 in. (3.2 mm) deep when running and will not operate successfully if started in only 1/8 in. (3.2 mm)
of water.
Airlock
This pump is a centrifugal utility pump, designed to efficiently remove water. However, it cannot move air. If air is
trapped inside the pump (a condition called “airlock”), the pump cannot pump water out even though the pump is
completely submerged. This unit does not have an anti-airlock hole. When you use the pump, please drain the water
out of the garden hose, keep the end of the hose out of the water, and plug in the power cord, starting the pump.
CARE AND CLEANING
CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns,
unplug the pump and allow time for it to cool after periods of extended use.
Do Do Not
When the power is disconnected, inspect the pump
suction screen and remove all debris, then plug the
pump back into the grounded (GFCI) outlet.
Do not disassemble the motor housing. This
motor has NO repairable internal parts, and
disassembly may cause leakage or dangerous
electrical wiring issues.
Do not lift up the pump by the power cord.
To clean a pump clogged with debris:
Unplug the pump from electrical power.
Remove debris from the screen (3).
Remove the screws (4) and take out the volute (3) from the pump and clean
the debris on the shaft (1) and impeller (2).
Reassemble the volute (3).