Westinghouse WH25U handleiding
Handleiding
Je bekijkt pagina 6 van 8

6
TROUBLESHOOTING
Problem
Possible Cause
Corrective Action
The pump does not start.
1. The fuse is blown.
2. The breaker is tripped.
3. The plug is disconnected.
4. The plug is corroded.
5. The motor failed.
6. Ice or blockage has locked the
impeller.
1. Replace the fuse.
2. Reset the breaker.
3. Secure the plug.
4. Clean the plug prongs.
5. Replace the pump.
6. Remove the blockage.
The pump is unable to pump out
water.
1. The screen is blocked.
2. The hose is kinked, bent sharply, or
coiled.
3. There is airlock.
4. The hose length is too long.
5. The impeller is loose on the shaft.
6. The impeller is broken.
1. Clean the screen.
2. Straighten the hose.
3. Clean the anti-air lock hole.
4. Use a shorter hose.
5. Reassemble the impeller.
6. Replace the impeller.
Bekijk gratis de handleiding van Westinghouse WH25U, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Westinghouse |
Model | WH25U |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 815 MB |