Ÿ Avoid termination locations near any air inlets.
Ÿ Near soffit vents or crawl space vents or other area
where condensate or vapor could create a nuisance
or hazard or cause property damage; or
Ÿ Avoid termination locations near commercial
cooking exhaust.
Ÿ Over public walkways; or
Ÿ Avoid termination locations near a dryer vent.
Check to determine whether local codes supersede
these clearances.
The vent for this appliance shall not terminate
Ÿ You must install a vent termination at least 12
inches above the ground or anticipated snow level.
Ÿ Do not install the vent termination too close under
the soffit where it could present recirculation of
exhaust gases back into the combustion air intake
part of the termination.
Ÿ Install vent termination such that exhaust and
rising moisture will not collect under eaves.
Discoloration to the exterior of the building could
occur if installed too close.
Ÿ Do not install vent termination under a soffit vent
such that exhaust can enter the soffit vent
Ÿ Where condensate or vapor could cause damage or
could be detrimental to the operation of regulators,
relief valves, or other equipment. Important
considerations for locating vent termination under
a soffit (ventilated or unventilated or eave vent; or
to a deck or porch)
NOTICE
1. In accordance with the current CSA
B149.1, Natural Gas and Propane
Installation Code.
5. The appliance should be located in an
area where leakage of the tank or
connections will not result in damage to
the area adjacent to the appliance or to
4. For other than a direct vent appliance, the
appliance must be located as close as
practicable to a chimney or gas vent.
2. In accordance with the current ANSI
Z223.1/NFPA 54, National Fuel Gas Code.
3. If locally adopted installation codes
specify clearances different than those
illustrated, then the most stringent
clearance shall prevail.
Installation
1. Identify the installation location and confirm that
the installation will meet all required clearances.
3.9 Mount to Wall
Additional clearances
NOTICE
The water heater must be installed in an
upright position. Do not install upside down
or on its side.
lower floors of the structure. When such
locations cannot be avoided, it is
recommended that a suitable drain pan,
adequately drained, be installed under the
appliance. The pan must not restrict
combustion air flow.
2. As shown on the right, first install the mounting
hole on the wall. The upper mounting hole is fixed
by the expansion screw, and the lower mounting
hole is inserted into the plastic plug. Hang the
water heater, place the washer and nut on top, and
tighten the nut. Screw on the self-tapping screws
below.
20