H =
Canadian installations
2
US installations
I =
J =
K =
6 in (15 cm) for appliances ≤ 10,000 Btu/h (3 kW), 12 in (30 cm) for
appliances >10,000 Btuh (3 kW) and ≤ 100,000 Btu/h (30 kW), 36 in (91
cm) for appliances >100,000 Btu/h (30 kW)
L =
M =
Above a regulator within 3 ft (91 cm)
horizontally of the vertical center line of
the regulator vent outlet to a maximum
vertical distance of 15 ft (4.5m)
Clearance to each side of cente* line
extended above meter/ regulator
assembly
Clearance to service regulator vent
outlet
*
Clearance to nonmechanical air supply
inlet to building or the combustion air
inlet to any other appliance
Clearance to a mechanical air supply
inlet
7 ft (2.13m) [1]
Clearance above paved sidewalk or
paved driveway located on public
property
6 ft (1.83 m)
Clearance under veranda, porch deck,
or balcony
12 in (30 cm) [2]
*
*
3 ft (91 cm) above if within
10 ft (3 m) horizontally
*
*
[1] A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single
family dwellings and serves both dwellings.
[2] Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
Description
Installation
Clearance to opposite wall is 24 inches (60 cm).
* For clearances not specified in ANSI Z223.1/NFPA 54, clearances are in accordance with local installation
codes and the requirements of the gas supplier.