Wachendorff WDGA 58S handleiding

34 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 31 van 34
Technical Manual
WDGA with IO-Link
4 - IO-Link
© Wachendorff Automation GmbH & Co. KG
25
0057
0
Operating hours
counter
RO
RecordT
Operating hours counter
1
Current operating
hours
RO
UINT32
Operating hours since the
last bootup
2
Total operating
hours
RO
UINT32
Operating hours since the
last reset (delivery)
0074
0
Operating hours
saving mode
RO
UINT8
0 = dynamic storage
mode
1 = static storage mode
0093
0
Pin 2 function
RW
RecordT
1
Pin 2 behaviour IO-
Link
RW
UINT8
0 = inactive
1 = active
2
Pin 2 mode
RW
UINT8
0 = inactive
3 = digital input
If pin 2 has been
configured as a digital
input, it can be used to
perform a preset.
00CE
0
Low signal quality
threshold
RW
UINT8
Determines the threshold
value for signal quality
bad.
00CF
0
Signal quality
RO
RecordT
1
Current signal
quality
RO
UINT8
0..100%
2
Signal quality status
RO
Boolean
0 = signal quality good
1 = signal quality bad
Table 4.9: Configuration and diagnostic parameters

Bekijk gratis de handleiding van Wachendorff WDGA 58S, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkWachendorff
ModelWDGA 58S
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5087 MB