Technical Manual
WDGA with IO-Link
4 - IO-Link
© Wachendorff Automation GmbH & Co. KG
25
0057
0
Operating hours
counter
RO
RecordT
Operating hours counter
1
Current operating
hours
RO
UINT32
Operating hours since the
last bootup
2
Total operating
hours
RO
UINT32
Operating hours since the
last reset (delivery)
0074
0
Operating hours
saving mode
RO
UINT8
0 = dynamic storage
mode
1 = static storage mode
0093
0
Pin 2 function
RW
RecordT
1
Pin 2 behaviour IO-
Link
RW
UINT8
0 = inactive
1 = active
2
Pin 2 mode
RW
UINT8
0 = inactive
3 = digital input
If pin 2 has been
configured as a digital
input, it can be used to
perform a preset.
00CE
0
Low signal quality
threshold
RW
UINT8
Determines the threshold
value for signal quality
bad.
00CF
0
Signal quality
RO
RecordT
1
Current signal
quality
RO
UINT8
0..100%
2
Signal quality status
RO
Boolean
0 = signal quality good
1 = signal quality bad
Table 4.9: Configuration and diagnostic parameters