Technical Manual
WDGA with IO-Link
4 - IO-Link
© Wachendorff Automation GmbH & Co. KG
24
denominator are also
ignored.
2
Velocity Numerator
RW
UINT16
Speed counter
3
Velocity
Denominator
RW
UINT16
Denominator of the speed
1172
0
Velocity Integration
Time
RW
UINT16
Integration time over
which the rotary encoder
determines its speed.
Changing the value
makes the speed value
slower (high time) or
more dynamic (low time).
Note: The default setting
is a good setting for most
applications.
1173
0
Velocity source
RW
UINT8
Source of speed
0 = scaled position
1 = Raw position
4080
0
MDCDescr
RO
RecordT
1
LowerLimit
RO
UINT64
0
2
UpperLimit
RO
UINT64
== Multiturn resolution
3
Unit
RO
UINT16
None
4
Scale
RO
INT8
Always 1
0070
0
Diagnosis
suppression level
configuration
RW
UINT8
Event suppression level
0 = all events
1 = Warnings and errors
2 = Errors
3 = No events
0071
Event code
suppression
RW
Array[5]
The event codes to be
suppressed can be
written in the fields of the
array.
1
suppressedEvents 0
RW
UINT16
2
suppressedEvents 1
RW
UINT16
3
suppressedEvents 2
RW
UINT16
4
suppressedEvents 3
RW
UINT16
5
suppressedEvents 4
RW
UINT16
0072
0
Event code
suppression Teach-
in
WO
UINT16
The event code entered
is written to a free field in
the array from 0x0071.
0073
0
Event code
suppression delete
WO
UINT16
The event code entered
is deleted from a field in
the array from 0x0071.
0058
0
Boot cycle counter
RO
RecordT
NA
1
Boot cycle counter
RO
UINT32
Counter for the number of
bootups