Technical Manual
WDGA with IO-Link
4 - IO-Link
© Wachendorff Automation GmbH & Co. KG
21
400E
0
SSC2ParamVelocity
RW
RecordT
1
HighLimit
RW
INT32
see above.
2
LowLimit
RW
INT32
see above.
400F
0
SSC2ConfigVelocity
RW
RecordT
1
Logic
RW
UINT8
see above.
2
Mode
RW
UINT8
see above.
3
Hysteresis
RW
INT32
see above.
0052
0
Operating
Temperature
RO
Array
Indicates the measured
temperature of the
internal temperature
sensor
1
Actual Operating
Temperature
RO
INT16
Current operating
temperature
2
Operating
Temperature Min
(Since last start)
RO
INT16
Lowest measured
temperature since the last
bootup
3
Operating
Temperature Max
(Since last start)
RO
INT16
Highest measured
temperature since the last
bootup
4
Operating
Temperature Min
(Lifetime)
RO
INT16
Lowest measured
temperature since first
bootup
5
Operating
Temperature Max
(Lifetime)
RO
INT16
Highest measured
temperature since first
bootup
0053
0
Operating
Temperature
Thresholds
RW
Array
1
Operating
Temperature Lower
Thershold
RW
INT16
Lower temperature
threshold (event)
2
Operating
Temperature Upper
Thershold
RW
INT16
Upper temperature
threshold (event)
0055
0
Device Variant
RW
UINT16
Setting the sensor profile
1 = SSP 4.2.1
2 = SSP 4.2.2
3 = 64-bit
00C1
Measurement Offset
RW
UINT64
The preset function shifts
part of the position value
to the offset. The offset
value is automatically
saved in the device and
can be used for
diagnostics.
Offset Value = Preset
Value - Position value