2. Slide heater element block partially into heat
shield assembly (tray), leaving enough space to
mount high limit bulb.
A. Apply heat sink compound between high
limit bulb and heater element block.
B. Secure high limit thermostat bulb to the
heater element block.
3. Slide heater block in until it stops then push
toward front of machine.
A. Raise heat shield assembly (tray) and install
mounting bolts to secure. Hand tighten only.
B. Tighten one of the inner bolts several turns
then move to other inner bolt. Continue
tightening all 4 bolts in an alternating pattern
until top of each heat mount strap contacts
bottom of cooking compartment flange.
Do not over tighten bolts or damage to heat mount
strap may occur.
Fig. 30
C. Ensure heat sink compound does not flow
onto low water thermostat (sensor) at rear
of compartment. If it does, remove excess.
4. Connect lead wires to 1CON and 2CON in noted
positions. Tighten screws to secure wires.
5. Install heat shield.
6. Check steamer for proper operation.
MANUAL DRAIN VALVE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
1. Remove right SIDE PANEL and REAR PANEL.
2. Remove pin and washer to disconnect the handle
linkage from linkage bracket.
Fig. 31
3. Remove nut and linkage bracket.
Fig. 32
4. Remove drain valve.
5. Reassemble parts removed in reverse order of
removal.
A. Apply pipe thread sealant to plumbing
threads before assembly.
6. Check steamer for leaks and proper operation.
C24EO SERIES ELECTRIC COUNTERTOP STEAMERS - REMOVAL AND REPLACEMENT OF PARTS