Vulcan C24DA10 handleiding
Handleiding
Je bekijkt pagina 17 van 65

Fig. 27
GENERATOR ASSEMBLY
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
All gas joints disturbed during servicing must be
checked for leaks. Check with a soap and water
solution (bubbles). Do not use an open flame.
A. CHECK ALL JOINTS PRIOR TO THE GAS
VALVE (SOLENOID) BEFORE LIGHTING THE
UNIT.
B. CHECK ALL JOINTS BEYOND GAS VALVE
(SOLENOID) AFTER UNIT IS LIT.
1. Drain the generator and allow steamer to cool, if
necessary.
Fig. 28
2. Remove rear and side panels.
3. Disconnect gas line at gas combination control
valve.
Fig. 29
NOTE: Earlier production units show in graphics.
C24GA AND C24DA SERIES CONVECTION STEAMER - REMOVAL AND REPLACEMENT OF PARTS
Page 17 of 65 F35425 Rev. E (0119)