3. Disconnect wires to burner assembly.
4. Remove the nuts securing burner to tank.
5. Drop blower end of burner assembly slightly
down to clear control box and push all interfering
wires out of the way so that burner can be pulled
out of tank.
6. Reverse procedure to install burner assembly.
GAS COMBINATION CONTROL
VALVE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
All gas joints disturbed during servicing must be
checked for leaks. Check with a soap and water
solution (bubbles). Do not use an open flame.
A. CHECK ALL JOINTS PRIOR TO THE GAS
VALVE (SOLENOID) BEFORE LIGHTING THE
UNIT.
B. CHECK ALL JOINTS BEYOND GAS VALVE
(SOLENOID) AFTER UNIT IS LIT.
1. Remove FRONT AND RIGHT SIDE PANELS.
2. Remove main burner as outlined in MAIN
BURNER.
3. Disconnect electrical supply wires running to gas
combination control valve.
Fig. 25
4. Disconnect pilot gas supply tube from control.
5. Disconnect pipe connections on each side of gas
combination control valve.
6. Reverse procedure to install.
7. Verify PILOT BURNER ADJUSTMENT (ONLY
UNITS WITH ADJUSTABLE PILOT).
NOTE: No pilot burner adjustment needed if unit has
Solaronics burner assembly.
ADJUSTABLE PILOT (1, Fig. 26) BURNER
SHOWN
Fig. 26
SOLARONICS BURNER ASSEMBLY (1, Fig.
27) NON-ADJUSTABLE PILOT
C24GA AND C24DA SERIES CONVECTION STEAMER - REMOVAL AND REPLACEMENT OF PARTS
F35425 Rev. E (0119) Page 16 of 65