Do not drive bearing into place. The inner door panel
could be damaged. Press bearing into position.
NOTE: When replacing door hinge bearings, replace
both hinge bearings.
9. Position replacement hinge bearing over hinge
opening in door assembly.
Fig. 21
10. Reassemble parts removed in reverse order.
11. Check door for fit and proper door gasket sealing.
MAIN BURNER
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
In the previous production (up to serial number
463024849) blower assembly components were
separate (gas valve, air pressure switch, blower, and
ignition module). Current production blower assembly
(starting at serial number 463024850) is one unit and
the air pressure switch is not required. The ignition
module has changed locations and the wire harness
is different. NOTE and VERIFY all wire connections.
PREVIOUS PRODUCTION SHOWN IN Fig. 22
Fig. 22
CURRENT PRODUCTION SHOWN IN Fig. 23
Fig. 23
1. Remove front and side covers as outlined under
COVERS AND PANELS.
2. Disconnect the gas line at gas combination
control valve.
Fig. 24
C24GA AND C24DA SERIES CONVECTION STEAMER - REMOVAL AND REPLACEMENT OF PARTS