4. Set SR_RISE and SR_FALL(the rising/falling slope of the voltage)
a) Fast b) Normal c) Slow
5. Set OVP, OCP, OPP
4.3.3 Constant Resistance Mode (CR)
When the user selects the SHIFT+ CV function key, the load enters constant
resistance mode (CR). In constant resistance operation mode, the electronic
load will behave as a constant resistor. The current will change linearly with
the input voltage. The relationship between voltage and current is shown in
the figure below.
Load
voltage
Load current
CR mode
The slope of the
straight line is
equal to the set
resistance value
Figure 4.3.3-1 CR mode: The Voltage-Current Relationship Diagram
Figure 4.3.3-2 CR mode operation interface