VigilLink VLDT-AP0808 handleiding
Handleiding
Je bekijkt pagina 35 van 39

- 33 / 37 -
Command
Code
Function Description
Example
Feedback
Default Setting
s in x expd on
attacktime z!
Set the attack time,
x=1~8,
z=1~500
s in 1 expd on
attacktime 10!
input 1 expander
is active and set
attacktime 10ms
s in x expd on
releasetime z!
Set the release time,
x=1~8,
z=1~10000
s in 1 expd on
releasetime 100!
input 1 expander is
active and set
releasetime 100ms
s in x expd off! Disable the Expander, x=1~8
s in 1 expd off!
input 1 expander
is unactive
Disable
Equalizer (input)
s in x peq on
band b on type z!
Set the filter type,
x=1~8,
b=1~8,
z=1(LP)
,
2(HP)
,
5(Peak)
s in 1 peq on
band 1 on type
5!
input 1 peq is
active
and set band 1
filter
to peak
s in x peq on
band b on frq z!
Set the frequency,
x=1~8,
b=1~8,
z=20~20000
s in 1 peq on
band 1 on frq
1000!
input 1 peq is
active
and set band 1
frequency 1000Hz
s in x peq on
band b on wide
z!
Set the Q value,
x=1~8,
b=1~8,
z=2~5000
s in 1 peq on
band 1 on wide
2!
input 1 peq is
active and set
band 1 wide 0.02
s in x peq on
band b on gain
z!
Set the gain value,
x=1~8,
b=1~8,
z=-240~180
s in 1 peq on
band 1 on gain
-60!
input 1 peq is
active
and set band 1 gain
-6.0dB
s in x peq on
band b off!
Disable the subband,
x=1~8,
b=1~8
s in 1 peq on
band 1 off!
input 1 peq is
active but band 1
is unactive
Disable
s in x peq off!
Disable the Equalizer,
x=1~8
s in 1 peq off!
input 1 peq is
unactive
Disable
Compressor
s in x comp on
threshold z!
Set the threshold,
x=1~8,
z=-600~0
s in 1 comp on
threshold -100!
input 1 compressor
is active and set
threshold -10.0dB
s in x comp on
rate z!
Set the compression rate,
x=1~8,
z=10~200
s in 1 comp on
rate 20!
input 1 compressor
is active and set
rate 2.0
s in x comp on
knee z!
Set the knee width,
x=1~8,
z=0~200
s in 1 comp on
knee 0!
input 1 compressor
is active and set
knee 0.0
s in x comp on
gain z!
Set the makeup gain,
x=1~8,
z=-120~180
s in 1 comp on
gain 30!
input 1 compressor
is active and set
makeup gain 3.0dB
s in x comp on
attacktime z!
Set the attack time,
x=1~8,
z=1~500
s in 1 comp on
attacktime 10!
input 1 compressor
is active and set
attacktime 10ms
s in x comp on
releasetime z!
Set the release time,
x=1~8,
z=1~10000
s in 1 comp on
releasetime 100!
input 1 compressor
is active and set
releasetime 100ms
s in x comp off!
Disable the Compressor,
x=1~8
s in 1 comp off!
input 1 compressor
is unactive
Disable
Auto Gain Control
s in x agc on
target z!
Set the target level,
x=1~8,
z=-200~0
s in 1 agc on
target -90!
input 1 agc is
active and set
target level -9.0dB
Bekijk gratis de handleiding van VigilLink VLDT-AP0808, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | VigilLink |
Model | VLDT-AP0808 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 6379 MB |