HUart (Uart Parameter Configuration)
<HUart></HUart>
It is used to configure the parameters of the third-party control serial port, such as the baud rate.
Field
><: Baud rate. The value can be 300, 600, 1200, 4800, 9600, 14400, 19200, 38400,
56000, 57600, or 115200.
Example
<HUart>9600</HUart>
Indicates: Set the baud rate of the serial port to 9600.
HDev (Device Information Configuration)
<HDe></HDev>
It is used to configure the IP address and the name of the device.
Field
ip:
New IP address
mask: Subnet mask
gtway: Gateway
name: Device name, less than or equal to 20 char characters.
(Note: Please make sure to input the correct information when configuring the IP address.)
Example
<HDev ip = "192.168.1.123" mask = "255.255.255.0" gtway = "192.168.1.1"
name = "XXX"></HDev>
Indicates: Set the IP address to 192.168.1.123, Subnet mask to 255.255.255.0,
gateway to 192.168.1.1, device name to XXX.
HSvCfg (Save Configuration)
<HSvCfg></HSvCfg>
It is used to deliver the command to enable the DSP to save the current configuration.
Field
None
Example
<HSvCfg></HSvCfg>
HSvScnce (Save Scene)
<HSvScnce></HSvScnce>
It is used to deliver the command to save the current configuration to the corresponding scene.
Field
no: Scene number, no=1~8.
Example
<HSvScnce no="7"></HSvScnce>
Indicates: Save the current configuration to Scene 7.
HRdScnce (Read Scene)
<HRdScnce></HRdScnce>
It is used to read the saved scene configuration file.
Field
no:
Scene number, no=1~8.
Example
<HRdScnce no="7"></HRdScnce>
Indicates: Read the configuration information of Scene 7.
HRstScnce (Reset Scene)
<HRstScnce></HRstScnce>
It is used to reset the corresponding scene to the factory default status.
Field
no: Scene number, no=1~8.
Example
<HRstScnce no="7"></HRstScnce>
Indicates: Reset the Scene 7 to the default configuration status.