<HExp no="2" opt="1" thrd="-450" rate="20" wd="0" atktm="10" rlstm="100"></HExp>
Indicates: Enable the Expander function on input channel 2, and set the threshold value to
-45dB, compression rate to 2, hard knee, attack time to 10ms, and release time to 100ms.
HCom (Compressor)
<HCom></HCom>
The Compressor is mainly used to compress signals larger than the threshold value, and control audio
signals within a certain threshold range.
Field
no: Channel number, no=0~7.
opt: Enable/disable switch, opt="0" (disable), opt="1" (enable).
thrd: Threshold value, thrd=-600~0.
rate: Compression rate, rate=10~200.
wd: Knee width, wd=0~200, wd="0"(Hard knee).
atktm: Attack time, atktm=1~500ms.
rlstm: Release time, rlstm=1~10000ms.
><: Makeup gain. The value range is [-120, 180].
Example
<HCom no="2" opt="1" thrd="-90" rate="20" wd="0" atktm="10" rlstm="100">30</HCom>
Indicates: Enable the Compressor function on input channel 2, and set the threshold value
to -9dB, compression rate to 2, hard knee, attack time to 10ms, release time to 100ms, and
makeup gain to 3dB.
HAgc (Auto Gain Control)
<HAgc></HAgc>
The AGC is mainly used to control the signal to the target level.
Field
no: Channel number, no=0~7.
opt: Enable/disable switch, opt="0" (disable), opt="1" (enable).
thrd: Threshold, thrd=-60~0.
lvl: Target level, lvl=-200~0.
rate: Compression ratio,rate=10~200.
><: Maximum gain value. The value range is [0, 120].
Example
<HAgc no="2" opt="1" thrd="-50" lvl="-90" rate="30">60</HAgc>
Indicates: Enable the AGC function on input channel 2, and set the threshold value to
-50dB, target level to -9dB, compression rate to 3, and maximum gain value to 6dB.
HLmt (Limiter)
<HLmt></HLmt>
The Limiter is a special case of the Compressor.
Field
no: Channel number, no=100~107.
opt: Enable/disable switch, opt="0" (disable), opt="1" (enable).
thrd: Threshold, thrd=-600~0.
rlstm: Release time, rlstm=1~10000ms.
Example
<HLmt no="102" opt="1" thrd="-90" rlstm="100"></HLmt>
Indicates: Enable the Limiter function on output channel 102 (i.e. the analog output
channel 3), and set the threshold to -9dB, and release time to 100ms.