Vevor EM5500-48L handleiding

352 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 23 van 352
- 21 -
29
Low DC cut-off
voltage
48V models default setting: 42.0V
24V models default setting: 21.0v
If self-defined is selected in program 5, this program can be set
up. Setting range is from 20.0V to 27.0V for 24v model and
40.0V to 54.0V for 48v model. The setting value must be less
than the value of program12. Increment of each click is
0.1V.Low DC cut-off voltage will be fixed to setting value no
matter what percentage of load is
connected.
32
Bulk charging
time (C.V
stage)
Automatically (Default) :
If selected, inverter will judge
this charging time automatically.
5 min
The setting range is from 5 min
to 900 min. Increment of each
click is 5 min.
900 min
If “USE” is selected in program 05, this program can be set up.
33
Battery equalization
Battery equalization
Battery equalization disable
(default)
If “Flooded” or User-Defined” is selected in program 05, this
program can be set up.

Bekijk gratis de handleiding van Vevor EM5500-48L, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkVevor
ModelEM5500-48L
CategorieNiet gecategoriseerd
TaalNederlands
Grootte56647 MB