26
Bulk charging
voltage (C.V
voltage)
48V models default setting: 56.4V
24V models default setting: 28.2V
If self-defined is selected in program 5, this program can be set
up. Setting range is from 24.0V to 30.0V for 24v model and
48.0V to 62.0V for 48v model. But the setting value must be
more than or equal the value of program27. Increment of each
click is 0.1V.
27
Floating charging
voltage
48V models default setting: 54.0V
24V models default setting: 27.0V
If self-defined is selected in program 5, this program can be set
up. Setting range is from 24.0V to the value of program 26 for
24v model and 48.0V to the value of program 26 for 48v model.
Increment of each click is 0.1V.