Vevor EM5500-48L handleiding
Handleiding
Je bekijkt pagina 19 van 352

- 17 -
07
Auto restart when
over temperature
occurs
Restart disable
Restart enable (default)
08
Output voltage
220V
230V (default)
240V
09
Output frequency
50Hz (default)
60Hz
10
Auto bypass
When selecting
“auto”, if the mains
power is normal, it
will automatically
bypass, even if the
switch is off.
manual(default)
auto
11
Maximum utility
charging current
30A (default)
If selected, acceptable charging current range will be within 2-
Max. AC charging current of SPEC.
12
Setting voltage point
back to utility source
when selecting “SBU
priority” or “Solar
first” in program 01.
48V models:
46V (default)
Setting range is from 44.0V to
57.2V for 48v model, but the
max setting value must be less
than the value of program13.
24V models:
23V (default)
Setting range is from 22.0V to
28.6V for 24v model, but The
max setting value must be less
than the value of program13.