Vevor EM5500-48L handleiding

352 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 18 van 352
- 16 -
02
Maximum charging
current: To configure
total charging current
for solar and utility
chargers.
(Max. charging
current = utility
charging current +
solar charging
current)
60A (default)
If selected, acceptable charging
current range will be from Max.
AC charging current to Max.
Charging current of SPEC but
it shouldn’t be less than the AC
charging currentprogram 11
03
AC input voltage
range
Appliances (default)
If selected, acceptable AC input
voltage range will be within
90-280VAC.
UPS
If selected, acceptable AC input
voltage range will be
within 170-280VAC.
Generator
If selected, acceptable AC input
voltage range will be within 170-
280VAC and compatible with
generators.
Note: Because generators are
unstable, maybe the output of
inverter will be unstable too.
05
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected,
battery charge voltage and low
DC cut-off voltage can be set up
in program 26, 27 and 29.
Support PYLON US2000
Protocol 3.5 Version
Standard communication
Protocol form inverter supplier
06
Auto restart when
overload occurs
Restart disable
Restart enable (default)

Bekijk gratis de handleiding van Vevor EM5500-48L, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkVevor
ModelEM5500-48L
CategorieNiet gecategoriseerd
TaalNederlands
Grootte56647 MB