RECORD OF SATISFACTORY CONDITION (THE “RECORD”)
Before using the STAND for the first time, make a written record of its appearance. Describe
the condition of the base, threaded feet, leveling pads, pedal mechanism, cylinder cover, set
screws, inner sleeve, and the roller subassembly. Take photographs of each item and add the
photos to your record. Take photographs of all labels applied to the stand. Describe in writing
where each label is located. Extend the cylinder/raise the roller subassembly by pumping the
pedal lever. Describe the effort needed to pump the pedal and how far the cylinder extends
with each pump of the pedal. Press and hold the pedal and press down the roller
subassembly to lower it. Describe the effort needed to lower the roller subassembly. Combine
all writings and photographs in a single file. This file is your record of the STAND-G in satisfactory
condition. When conducting the following inspections, compare your observations to this
RECORD to determine whether it is in satisfactory condition. Do not use the STAND unless every
component is in satisfactory condition. Cosmetic changes, like damaged paint/powder coat
do not constitute changes from satisfactory condition. However, touchup paint should be
applied to all affected areas as soon as damage occurs.
INSPECTIONS
Inspections and repairs should only be performed by qualified persons. Compare the results
of each inspection to the RECORD OF SATISFACTORY CONDITION (the “RECORD”). Do not use
the STAND unless all parts are in satisfactory condition. Replace parts that are not in
satisfactory condition before returning the STAND to service. DON’T GUESS! If you have any
questions about the condition of your product, contact the TECHNICAL SERVICE department.
The phone number is provided on the cover page of this manual.
Never make temporary repairs of damaged or missing parts. Only use manufacturer-
approved replacement parts. Replace the entire unit if it cannot be restored to satisfactory
condition.
Monthly inspections
Perform the following inspections at least once per month, or immediately after any
incident occurs which reasonably should be expected to cause damage to the STAND.
1. Check the surface of the STAND for dirt, corrosion, or other matter. Clean the STAND when
necessary.
2. Confirm integrity of hardware and fasteners, including but not limited to bolts, nuts,
threaded feet, and set screws.
3. Raise the roller subassembly by pumping the foot pedal. Determine whether the cylinder
extends normally. If the roller elevates while pumping the pedal, but descends slowly on its
own, or if you observe any other form of abnormal, unstable or noisy movement of the
cylinder, contact the TECHNICAL SERVICE DEPARTMENT
4. Examine the base. All 3 threaded feet should make solid contact with the ground. The
STAND must not wobble. Check each foot for looseness or excessive wear or other forms of
damage.
5. Confirm that the roller subassembly is in satisfactory condition. Both rollers should freely spin
with little resistance.
6. Check labels. See LABELING DIAGRAM on p. 8. Replace labels that are damaged, missing,
or not easily readable.
7. Examine the whole structure for rust/corrosion/metal erosion. Remove rust/corrosion with a
steel bristle brush or steel wool. Clean the area and apply touchup paint. Metal erosion
might require removing the STAND from service. Contact TECHNICAL SERVICE if you have
any questions.