• Strip the cable endlong enough (30 mm ±5 mm)tobe
fully clamped. Otherwise, its outer jacket prevents the
cable conductor from being tightly secured, causing poor
contact.
[Connecting the battery]
Note correct polarity (positive and negative orientation) when connecting
the power supply cord. Reversed polarity connections will cause damage
to the system.
• Insertthebatterycableintothecorrectpositioninthebatteryterminalreferringtotheterminal'scrosssectional
diagrams below.
18 kΩ (1/4 W)
Battery Battery
Notes
To avoid battery failure and charger failure, take care of the following points.
• Ifbatteriesnotrecommendedbythemanufacturerareusedandachargerfailureoccurs,connectaresistor
of18kΩ(1/4W)paralleltothebatteries.
• Usethespecifiedtypeofbatteriesandcapacity.
• Whenbatteriesareconnectedtogetherinaseries-parallelarrangement,theinter-connectingcablesmustbe
of equal length and resistance to insure equalization of the load.
• Donotmixbatterieswithdifferentcapacity,newandoldbatteries,orbatteriesofdifferentmanufacturers.
Doing so may cause different characteristic values among batteries, possibly resulting in damage to the
batteries themselves or the connected equipment.
CAUTION
Correct position of the cable insertion Incorrect position of the cable insertion
Wrong insertion position of the cable or a forked
cableinsertioncausespoorcontactorinsufcient
connection tightness, making the cable come off to
possibly cause short-circuit accident.
Correct Incorrect
Cable conductor
Cable clamp