Display
Standby-Mode
In standby mode, the heat pump is ready for operaon but deacvated. The water is neither heated nor cooled.
By pressing the buon On/O
12
the heat pump switches between standby mode and operang mode.
Acve display elements:
» The display Temperature
15
shows the current water temperature.
» The display me/mer
24
shows the current me.
Operang modes
By pressing the buon Mode/key lock
14
the heat pump switches between the operang modes. The set water
temperature can be between +10°C and +45°C.
The heat pump has the following operang modes:
1. Operang mode heang
The heat pump heats the pool water to the set temperature.
2. Operang mode cooling
The heat pump cools the pool water to the set temperature.
3. Operang mode auto
The heat pump regulates the temperature of the pool water by heang or cooling it to the set target
temperature.
4. Operang mode defrost
At low ambient temperatures, the temperature at the heat exchanger can drop so low in heang mode
that the condensaon water freezes and the heat exchanger ices up. The heat pump monitors the
temperature at the heat exchanger and defrosts automacally if necessary.
F
12
24
15
14
Acve display elements in operang mode:
» Operang mode: The display defrost-mode
19
, cooling-mode
20
, automac-mode
21
or heang-
mode
22
lights up.
» Power level: The display silent-mode
16
, smart-mode
17
or power-mode
18
lights up.
» The display temperature
15
shows the current water temperature at the water connecon input
7
(In)
or, ashing, the set brine temperature (set).
» The display mer ON/OFF
23
provides informaon about the me control. If the symbol „1“ lights up,
mer 1 is acvated. If the symbol „2“ lights up, mer 2 is acvated
» The display me/mer
24
displays the current me.
Power levels
By pressing the buon power level
10
the heat pump switches between the silent, smart and power performance
levels of the heang and cooling operang modes.
There are 3 power levels to choose from for each of the heang and cooling operang modes:
1. Power level silent
The heat pump minimizes noise development.
This power level reduces the cooling and heang output.
2. Power level smart
The heat pump opmizes the output required to reach the set target temperature through stepless control.
This output level oers the best compromise between energy saving and the me it takes to reach the set
target temperature.
3. Power level power
The heat pump operates at maximum output.
This power level minimizes the cooling and heang me of the pool water.
Save energy
To reduce energy consumpon and the associated costs, you can take the following measures:
» If you do not use the pool for more than a week, switch o the heat pump or reduce the set water
temperature.
» Do not use the heat pump if the ambient temperature falls below 5°C.
» Cover the pool to protect it from heat loss.
G
10
24
23
16
15
17 18 19 20 21 22