Operaon
WARNING!
Danger to life due to operaon of the water treatment system while bathing!
Hair or items of clothing can be sucked in at the sucon opening of the pool and, in extreme cases, trap people
under water and prevent them from surfacing.
» Never operate water treatment system devices while people are in the pool.
» Prevent any access to the pool while water treatment system devices are in operaon.
ATTENTION!
Risk of injury!
A damaged device or damaged accessories can lead to injuries.
» Check the device and accessories (see chapter Checking).
NOTE!
Reduced or blocked venlaon of the heat pump can lead to inadequate removal of heat or moisture. This can
cause mold growth or overheang of the nned heat exchanger, for example.
» Clean the grille in front of the fan impeller and the ns of the heat exchanger regularly and ensure that no
impuries such as leaves or similar get inside the heat exchanger.
» Ensure that the grille on the heat exchanger is never covered and that air can ow freely through the
appliance.
Acvate heang
Select this operang mode if your pool water temperature is permanently below your desired temperature.
The pool water is heated most quickly when the heat pump is operang at maximum ow rate (see
Technical data on page 54). As a result, the temperature dierence between the pool water and the
heated water at the pool inlet is smaller and therefore less noceable. Please measure and note the
change in the current water temperature every 30 minutes to determine the actual heang of the pool water.
Acvate heang operang mode
1. Switch on the lter system.
The heat pump requires sucient water ow for operaon.
2. Deacvate the key lock, if it is acve, by pressing and holding the buon mode/key lock
14
for 3
seconds.
The display key lock
26
expires.
The key lock
26
acvates automacally aer 60 seconds of inacvity.
3. Press and hold the buon on/o
12
for 3 seconds.
The heat pump switches from standby mode to operang mode.
4. Press (repeated) the buon mode/key lock
14
unl the desired operang mode is acve.
The display heang-mode
22
lights up.
Analog to the operang mode heang, the automac operang mode can also be set as an alternave.
The heang operang mode is acvated.
If the error code „E 03“ appears on the display, the water ow through the heat pump is too low. You
can increase the ow rate using the 3-way valve of a by-pass set. Please also refer to the more detailed
informaon in the Troubleshoong chapter on page 54.
Seng the set temperature
1. Deacvate the key lock, if it is acve, by pressing and holding the buon mode/key lock
14
for 3
seconds.
The display key lock
26
expires.
The key lock
26
acvates automacally aer 60 seconds of inacvity.
2. Press (repeated) the buon down
11
or buon up
13
, unl the desired setpoint temperature is set.The
display temperature
15
ashes to indicate the desired setpoint temperature.
3. Press the buon on/o
12
, to conrm your entry.
The heat pump starts as soon as the input temperature (In) falls below the set target temperature (Set).
The desired setpoint temperature is set.
Seng the power level
1. Deacvate the key lock, if it is acve, by pressing and holding the buon mode/key lock
14
for 3
seconds.
The display key lock
26
expires.
The key lock
26
acvates automacally aer 60 seconds of inacvity.
2. Press (repeated) the buon power level
10
, unl the symbol for the desired power level lights up on
the display.
Each me you press the buon, the silent-mode
16
, smart-mode
17
and power-mode
18
indicators
on the display change.
The desired power level is set.
Acvate cooling
Select this operang mode if your pool water temperature is permanently above your desired temperature,
e.g. due to sunlight, and does not cool down enough during the night.
The pool water is heated most quickly when the heat pump is operang at maximum ow rate (see
Technical data on page 54). As a result, the temperature dierence between the pool water and the
heated water at the pool inlet is smaller and therefore less noceable. Please measure and note the
change in the current water temperature every 30 minutes to determine the actual heang of the pool water.
Acvate cooling operang mode
1. Switch on the lter system.
The heat pump requires sucient water ow for operaon.
2. Deacvate the key lock, if it is acve, by pressing and holding the buon mode/key lock
14
for 3
seconds.
The display key lock
26
expires.
The key lock
26
acvates automacally aer 60 seconds of inacvity.
3. Press and hold the buon on/o
12
for 3 seconds.
The heat pump switches from standby mode to operang mode.
4. Press (repeated) the buon mode/key lock
14
unl the desired operang mode is acve.
The display cooling-mode
20
lights up.
Analogous to the operang mode cooling, the automac operang mode can also be set as an alternave.
The cooling operang mode is acvated.
If the error code „E 03“ appears on the display, the water ow through the heat pump is too low. You
can increase the ow rate using the 3-way valve of a by-pass set. Please also refer to the more detailed
informaon in the Troubleshoong chapter (see Troubleshoong on page 52).