Operaon
WARNING!
Danger to life due to operaon of the water treatment system while bathing!
Hair or items of clothing can be sucked in at the sucon opening of the pool and, in extreme cases, trap people
under water and prevent them from surfacing.
» Never operate water treatment system devices while people are in the pool.
» Prevent any access to the pool while water treatment system devices are in operaon.
ATTENTION!
Risk of injury!
A damaged device or damaged accessories can lead to injuries.
» Check the device and accessories (see chapter Checking).
NOTE!
Reduced or blocked venlaon of the heat pump can lead to inadequate removal of heat or moisture. This can
cause mold growth or overheang of the nned heat exchanger, for example.
» Clean the grille in front of the fan impeller and the ns of the heat exchanger regularly and ensure that no
impuries such as leaves or similar get inside the heat exchanger.
» Ensure that the grille on the heat exchanger is never covered and that air can ow freely through the
appliance.
Acvate heang
Select this operang mode if your pool water temperature is permanently below your desired temperature.
The pool water is heated most quickly when the heat pump is operang at maximum ow rate (see
Technical data on page 54). As a result, the temperature dierence between the pool water and the
heated water at the pool inlet is smaller and therefore less noceable. Please measure and note the
change in the current water temperature every 30 minutes to determine the actual heang of the pool water.
Acvate heang operang mode
1. Switch on the lter system.
The heat pump requires sucient water ow for operaon.
2. Deacvate the key lock, if it is acve, by pressing and holding the buon mode/key lock
14
for 3
seconds.
The display key lock
26
expires.
The key lock
26
acvates automacally aer 60 seconds of inacvity.
3. Press and hold the buon on/o
12
for 3 seconds.
The heat pump switches from standby mode to operang mode.
4. Press (repeated) the buon mode/key lock
14
unl the desired operang mode is acve.
The display heang-mode
22
lights up.
Analog to the operang mode heang, the automac operang mode can also be set as an alternave.
The heang operang mode is acvated.
If the error code „E 03“ appears on the display, the water ow through the heat pump is too low. You
can increase the ow rate using the 3-way valve of a by-pass set. Please also refer to the more detailed
informaon in the Troubleshoong chapter on page 54.
Seng the set temperature
1. Deacvate the key lock, if it is acve, by pressing and holding the buon mode/key lock
14
for 3
seconds.
The display key lock
26
expires.
The key lock
26
acvates automacally aer 60 seconds of inacvity.
2. Press (repeated) the buon down
11
or buon up
13
, unl the desired setpoint temperature is set.The
display temperature
15
ashes to indicate the desired setpoint temperature.
3. Press the buon on/o
12
, to conrm your entry.
The heat pump starts as soon as the input temperature (In) falls below the set target temperature (Set).
The desired setpoint temperature is set.
Seng the power level
1. Deacvate the key lock, if it is acve, by pressing and holding the buon mode/key lock
14
for 3
seconds.
The display key lock
26
expires.
The key lock
26
acvates automacally aer 60 seconds of inacvity.
2. Press (repeated) the buon power level
10
, unl the symbol for the desired power level lights up on
the display.
Each me you press the buon, the silent-mode
16
, smart-mode
17
and power-mode
18
indicators
on the display change.
The desired power level is set.
Acvate cooling
Select this operang mode if your pool water temperature is permanently above your desired temperature,
e.g. due to sunlight, and does not cool down enough during the night.
The pool water is heated most quickly when the heat pump is operang at maximum ow rate (see
Technical data on page 54). As a result, the temperature dierence between the pool water and the
heated water at the pool inlet is smaller and therefore less noceable. Please measure and note the
change in the current water temperature every 30 minutes to determine the actual heang of the pool water.
Acvate cooling operang mode
1. Switch on the lter system.
The heat pump requires sucient water ow for operaon.
2. Deacvate the key lock, if it is acve, by pressing and holding the buon mode/key lock
14
for 3
seconds.
The display key lock
26
expires.
The key lock
26
acvates automacally aer 60 seconds of inacvity.
3. Press and hold the buon on/o
12
for 3 seconds.
The heat pump switches from standby mode to operang mode.
4. Press (repeated) the buon mode/key lock
14
unl the desired operang mode is acve.
The display cooling-mode
20
lights up.
Analogous to the operang mode cooling, the automac operang mode can also be set as an alternave.
The cooling operang mode is acvated.
If the error code „E 03“ appears on the display, the water ow through the heat pump is too low. You
can increase the ow rate using the 3-way valve of a by-pass set. Please also refer to the more detailed
informaon in the Troubleshoong chapter (see Troubleshoong on page 52).